Features:
8"TFT Color LCD shows the working status and ECG waveform. Check the waveform before printing to save record paper.
12 Leads ECG simultaneous acquisition, digital signal processor, to get higher quality ECG waveforms through the AC filter, baseline filter and EMG filter of the ECG signals.
Simultaneous display of 3/6/12 leads ECG waveform, and the state of printing mode, sensitivity, speed, filter etc, to be easy for interpretation.
Include multiform printing modes and formats, such as 12\6+1(rhythm)\6\rhythm 12\rhythm 10\rhythm 8\rhythm 6\Manual\Freeze etc; the length of wave printing can be adjusted and the function of periodic printing is included to satisfy different applications.
The instrument has the function of regular auto-analysis and auto-interpretation of ECG waveform parameter, provide measurement parameters such as HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc and auto-interpretation conclusion to help reducing doctor's abundance and improve working efficiency.
The power supply includes both AC/DC. This device includes built-in lithium polymer rechargeable battery. It can standby for 4 hours, print 150 pieces of
ECG waveform and print 90 minutes continually under the best DC state to satisfy the need of visiting patients and physical examination.
It has build-in storage with large capacity, and can memory more than 1000 cases, which is easy for doctor review and statistic.
Support Chinese, English, Spanish and Turkish Operating interface, can print out Multi-language report formats .
Include multiform printing speeds such as 5mm/s, 6.25mm/s ,10mm/s, 12.5mm/s, 25mm/s, 50mm/s. Provide graphic result format for visual diagnostic.
Main Technical Specification
Safety Type Class I, Type CF
Lead Standard 12 leads
Input way: Floating and defibrilation protection
Patient leak current <10µA
Sampling rate 1000Hz
A/D conversion 12bit
Frequency response 0.05Hz~150Hz (-3dB, + 0.4dB)
CMRR >60dB, >100dB( Add filter)
Enduring polarization voltage ±300mV
Noise level ≤15µVp-p
EMG interference filter 25/35Hz (-3dB)
AC filter 50/60Hz (≥20dB)
Recording way Thermal printing system
Recording paper 210mm(W)×20m(L)
Sensitivity 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV , Auto.
Paper speed:
Auto-record: 25mm/s, 50mm/s
Rhythm record:25mm/s, 50mm/s
Manual-record:5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
Freeze record:5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
AC 110V/220V, 50Hz/60Hz
DC 14.8V, 3700 mAh rechargeable lithium polymer battery
Fuse Specification 2 pcs φ5×20mm AC time lag; T250mA/250V(Power Supply: 220V)
Size: 340mm(L)×320mm(W)×85mm(H)